Operation Mode Selection Switch

OFF¡GWhen the switch is in the OFF 

            position, the slide cannot be operated

            , and only the main motor can be

            actuated.

INCHING¡GWhen the switch is in the 

                      INCHING position and the

                      Run Button is held, the slide

                      will be in motion and it will 

                      stop once the Run Button is

                      released.

CONT.¡GThe slide will operate in CONT. 

                mode , under following four

                conditions: 1) the Main Motor is

                actuated in FWD mode, 2) SPM

                value is above the minimum SPM,

                3) the slide is at the T.D.C. and 4)

                there is no abnormal status. If the

                Run Button is held less than five

                seconds, The slide will operate in

                INCHING mode. Otherwise ( held

                more than five seconds ) , the

                slide will operate in CONT. mode.

                The slide will stop at the T.D.C. ,

                if the Cont. Stop Button is pressed 

SAFETY ONE STROKE¡GThe slide will 

                      operate in SAFETY ONE 

                      STROKE mode , under 

                      following four conditions: 1) 

                      the Main Motor is actuated in 

                      FWD mode, 2) SPM value is 

                      above the minimum SPM, 3) 

                      the slide is at the T.D.C. and 

                      4) there is no abnormal 

                      status. If the Run Button is

                      held and released before

                      165¢X ( SAFETY ONE 

                      STROKE Preset Slide Angle ) ,

                      the slide will operate in 

                      INCHING mode. Otherwise

                      ( after 165¢X) , the slide will

                      operate in SAFETY ONE

                      STROKE mode.

Hand/Foot Switch

Hand or Foot operation mode can be switched.